Installation - Con-cur Dryer Booster Fan Control

IMPORTANT: Turn electricity off at circuit breaker or fuse panel. A licensed electrician is the best person to install this equipment. Be sure to adhere to local provisions and national electrical codes. Verify industry standards prior to installation.

INSTALLATION MODEL 1
Inside Dryer

1. Mount the Con-Cur current sensor in convenient location inside dryer connection compartment.
2. Disconnect and loop neutral (white) dryer power supply wire through current sensor cutout, then re-connect.
3. Connect fan 120v-AC power supply to top (relay) terminals of Con-Cur Control.

INSTALLATION MODEL 2
At Dryer Junction Box

1. Attach electrical junction box to dryer junction box.
2. Disconnect and loop neutral (white) dryer power supply wire through current sensor cutout, then back to dryer junction box and re-connect.
3. Mount Con-Cur current sensor in electrical box (may require drilling 2 mounting holes).
4. Connect fan 120v-AC power supply to top (relay) terminals of Con-Cur Control.

INSTALLATION MODEL 3
At Breaker

1. Mount Con-Cur current sensor in convenient location on fuse/breaker panel.
2. Disconnect and loop neutral (white) dryer power supply wire through current sensor cutout, then re-connect.
3. Connect fan 120v-AC power supply to top (relay) terminals of Con-Cur Control.